Friday, October 26, 2012

Occupational Health: Protecting workers Against Chemical Exposures

Infection Control Today recently ran an article written by Kelly Pyrek, with the above title that highlights the risks of chemical exposure to healthcare workers.

The author noted that "Occupational exposure to chemicals is common and frequent in hospitals" and went on to say that self reported exposures tend to be significantly under reported. The article looked at both respiratory and dermal exposures. Respiratory exposures arose in particular from sprayed cleaning chemicals and not only resulted in irritation but twice the rate occupational asthma compared to the general work environment. Occupational Asthma was especially prevalent among healthcare workers involved in medical instrument cleaning and exposed to general cleaning products and disinfectants. Dermal exposures mainly arose via contact with the hands due to inadequate protection.

The importance of using personal protective equipment (PPE), and receiving proper training on how to use it was emphasized including gloves, goggles and masks. Some discussion was also given to the use of alternative "Environmental Cleaning Chemicals" but efficacy concerns limit what can be used. The article summarized that there are many actions that can be taken involving different chemicals, modified work practices and better training that can have a major impact.

ChemDAQ has often stressed the importance of workers being aware of the risks of exposure to sterilant chemicals and this article shows that even common cleaning chemicals present a health risk to workers. Patient Safety is of paramount concern in healthcare, and the prevalence of hospital acquired infections has resulted in greater emphasis on disinfection and cleaning. Unfortunately, it is all too easy for hospital administrators to focus so much on patient safety that the safety of their employee gets over looked.

As the NIOSH NORA report stated "The HCSA sector is burdened by the historical and entrenched belief that patient care issues supersede the personal safety and health of workers and that it is acceptable for HCSA workers to have less than optimal protections against the risks of hazardous exposures or injuries." However, there are signs that the old ways are changing. Recent articles have discussed this issue, and more enlightened institutions know that patient safety and employee safety go hand in hand.

It almost goes without saying that any chemical used to kill a broad spectrum of microbial life is likely to have adverse effects on people exposed to it. Some of the effects will be immediate, others may take longer to become apparent. This article in Infection Control Today is valuable in informing people that occupational exposure to even every-day cleaning agents can have adverse effects. Disinfectant and cleaning chemicals provide life saving functions in healthcare, but whenever these chemicals are employed it is important to assess the risks, develop work practices to minimize exposure, provide adequate PPE, and train workers how to use these chemicals safely.

Tuesday, October 2, 2012

The ECHA is a Valuable Source of Chemical Safety Information

Often users, managers and industrial hygienists want to know the hazards associated with the chemicals that they use. There are many resources available for information on chemical hazards, including governmental and private sources. One of the more comprehensive sources is the European Chemical Agency (ECHA). The ECHA provides a lot of information in a relatively simple to use format; but this database is not widely known on this side of the Atlantic.

The ECHA has the goal to be the preeminent source for chemical safety information in the world. This agency was created under the European Union’s REACH program. REACH stands for the Registration, Evaluation, Authorization and Restriction of Chemical substances and went into law June 2007. Manufacturers and importers are required to gather information, including safety information, on the chemicals they manufacture, and to provide it to the ECHA which in turn provides public access to this information via an on-line searchable database. This database is a great resource for anyone looking to find safety information about chemicals commonly used in the workplace. Using peracetic acid (PAA) as an example, the ECHA search engine for hazardous chemicals is available at http://echa.europa.eu/web/guest/information-on-chemicals/registered-substances. Simple enter “peracetic” into the search line and click on the disclaimer box brings up a link to the dossier for PAA. Click on view to access the information. The information is divided into nine general categories:

    General Information

    Classification and Labelling

    Manufacture, Use & Exposure

    Physical and chemical properties

    Environmental fate and pathways

    Ecotoxicological Information

    Toxicological information

    Guidance on safe use

    Reference substances

For those people who want more general information, the Guidance on Safe Use Section provides general advice on using PAA, first aid measures, labels, exposure levels (for acetic acid and hydrogen peroxide) etc.

For those people who want more detail, for example information on research conducted on the chemical safety aspects of a particular compound, this level of information, chemical compatibility, is also available. Clicking on Toxicological Information generates the following submenu:

    Toxicological information.001

    Toxicokinetics, metabolism and distribution

    Acute Toxicity

    Irritation / corrosion

    Sensitisation

    Repeated dose toxicity

    Genetic toxicity

    Carcinogenicity

    Toxicity to reproduction

Selecting Acute Toxicity

    Acute toxicity: oral

    Acute toxicity: inhalation

    Acute toxicity: dermal

    Acute toxicity: other routes

The Acute Toxicity Inhalation section gives a list of 14 summaries of research studies on the acute inhalation toxicity of PAA. The long menu structures above are included in order to give an idea of how much information is available at this website.

This website offers a lot of safety information in summary form that is easy to use for the individual who just needs general guidance, but the website also has a lot of other information for those people who need more detail.

Friday, September 21, 2012

LEL and Other Combustible Gas Concentration Units

We are all used to converting units from metric to standard and from US standard to UK standard (a UK gallon = 1.20 US Gallons) but gas concentrations take it to a new level of complexity. We have absolute concentrations: mg/m3, relative concentrations: % ppm, ppb, and flammable concentrations: % LEL and probably some others I have not thought of. This article will try to explain the differences between these units and why people use one over another.

A true concentration is the amount of gas present per unit volume. For this reason, many gas concentrations are given in units of mg/m3. While this unit is correct, and is widely used in government regulations and industrial hygiene, it is more common to use relative units such as parts per million (ppm) or parts per billion (ppb). Relative units such as ppm and percent have the advantage that they do not change with pressure.

Oxygen in the air is about 20.9 % by volume (for any volume of air, 20.9 % of it is oxygen). Room air is 20.9% and so is compressed air in a scuba diver’s tank at ~ 2,000 psi. Similarly if I want to calibrate a gas monitor with 10 ppm of for example carbon monoxide, I can purchase a cylinder of 10 ppm carbon monoxide at 2,000 psi and deliver it to my gas monitor at close to atmospheric pressure and it is still 10 ppm. If one were working in mg/m3, the concentration at 2000 psi would be about 135 times as high as at ambient pressure because for every unit of volume there is 135 times more gas present. Since these relative concentrations are by volume of gas, they are sometimes written as ppmv, ppbv or % v/v in order to distinguish other relative measures such as ppm in liquids which are normally by weight.

One difficulty that arises is that many toxic gas sensors respond to the concentration of gas rather than the relative concentration. Thus if a gas sensor is calibrated at sea level and then shipped to Denver, (5,280 ft), the pressure is about 80% of sea level and so the absolute concentration will of any gas component will be lower than at sea level for the same ppm or % volume. Users of ChemDAQ products will be pleased to know that altitude is not an issue for their equipment since there is an automatic compensation parameter set in the monitor at the time of installation to correct for differences in altitude between ChemDAQ (where the sensor modules are calibrated) and the end user. LEL sensors also respond to the concentration and depending on how the sensor is constructed, some oxygen sensors respond to the absolute concentration, and others to the relative concentration.

Most of us however, happily live our lives at relatively constant atmospheric pressure and so the two units are readily interconvertible (see free ChemDAQ ppm to mg/m3 converter on the ChemDAQ website [bottom of page]) and we can use relative units without problem.

Another reason for using relative units occurs with flammable gases where percent LEL is widely used. Most flammable gases have a concentration range over which mixtures with air will burn. If there is too little fuel then there is insufficient heat produce for the flame to propagate and similarly if there is too little oxygen, again there is too little heat for the flame to propagate. A typical gas such as propane has flammability/explosive limits in air of 2.2 to 9.5 % by volume. [Matheson Gas Data Book, 6th Ed.], so any propane/air mixture in this range is flammable and so is potentially explosive. The lower limit of flammability is called the Lower Explosive Limit (LEL) and the other limit is the Upper Explosive Limit (UEL). The LEL and UEL values vary from gas to gas.

If one working in an environment where there is a risk of an explosive gas mixture forming, then no-one really cares if the concentration is 2.1% volume, they want to know whether the atmosphere is explosive or not and whether they should get out. Flammable gas monitors for workplace safety are therefore calibrated in % LEL which provides an immediate measure of the risk of forming an explosive atmosphere. The gas monitors typically have a range of 0 to 100% LEL. If the concentration reaches 100% LEL, then there is a potentially explosive atmosphere and so the alarms are set lower, typically 10% and 20% LEL.

To convert from % LEL to ppm, it is necessary to know the Lower Explosive Limit. Using ethylene oxide (EtO) as an example, the LEL is 3% by volume, which is equal to 30,000 ppm. It is common therefore in facilities that use large amounts of EtO to have two different types of monitor. One set of monitors measures EtO at parts per million concentrations to warn about potentially toxic exposures (OSHA Permissible exposure limit for EtO is 1 ppm calculated as an 8 hr Time weighted average) the other set of monitors is to detect potentially flammable gas mixtures that threaten not only people but also the building. Hopefully before the LEL monitors go into alarm the ppm levels alarms will have warned everyone to clear the air, but the LEL monitors are used to increase ventilation or turn on the sprinkler system.